Reusable Gasket-Sealed Electrolyte Cell / Metal Fuel Cell Reactor

Reusable Gasket-Sealed Electrolyte Cell Reactor for Metal Fuel Cell Testing

WEVIO Reusable Gasket-Sealed Electrolyte Cell Reactor for Metal Fuel Cell Testing

Send Email:

Products DETAILS

Reusable Gasket-Sealed Electrolyte Cell / Metal Fuel Cell Reactor

This reusable gasket-sealed electrolyte cell is a transparent zinc-air battery test mold and metal fuel cell reactor designed for controlled electrochemical experiments. Its sealed structure supports convenient tubing connections, while the transparent acrylic (PMMA) body allows researchers to observe the test components and electrolyte behavior during operation. This compact device combines a defined reaction area with an external electrolyte circulation system, making it suitable for repeatable laboratory testing.

The device is suitable for zinc-air battery research, metal fuel cell development, electrolyte circulation studies, and oxygen-fed electrochemical experiments. It supports optional reaction areas ranging from 1 to 4.5 cm², multiple tubing connector sizes, and external pump flow rates to accommodate different testing conditions. It is suitable for battery laboratories, advanced materials research, academic electrochemistry projects, and development work involving circulating electrolytes.

The sealed design helps maintain a controlled testing environment, while the 304 stainless steel screws and nuts provide durable mechanical fastening. Continuous electrolyte circulation can replenish consumed ions, reduce anode passivation, and minimize concentration polarization during high-current charge and discharge processes. These features support stable operation when researchers require consistent testing conditions and practical control over the fluid circulation loop.

Key Features

  • Reusable Gasket-Sealed Cell Design: The sealed structure provides a defined electrolyte chamber and convenient tubing connections for repeated zinc-air and metal fuel cell experiments. This configuration helps researchers maintain consistent assembly conditions across multiple tests.

  • Transparent Acrylic Construction: The acrylic mold allows direct visual inspection of the cell body and internal testing environment. Its transparent structure is particularly useful for observing electrolyte circulation, assembly conditions, and visible changes during experiments.

  • External Electrolyte Circulation: An external circulation pump moves the electrolyte through the test system at selectable flow rates of 3–10 mL/min or 20–65 mL/min. These two flow-rate options accommodate different experimental requirements and circulation intensities.

  • Improved Electrochemical Testing Control: Continuous electrolyte circulation can replenish ions consumed during reactions and reduce concentration gradients. This helps limit anode passivation and concentration polarization during high-current charge and discharge testing.

  • Multiple Reaction Area Options: Available configurations provide reaction areas of 1, 2, 3, 4, and 4.5 cm². Researchers can select an appropriate active area for material screening, comparative testing, or experiments requiring different current densities.

  • Oxygen-Compatible Gas Connections: Tubing connectors are available in 6, 8, and 10 mm sizes. The connections support pure oxygen testing when oxygen supply is required by the laboratory test protocol.

  • Durable Fastening Hardware: The screws and nuts are made of 304 stainless steel, providing secure clamping and reliable mechanical support during repeated cell assembly and laboratory use.

  • Flexible Electrolyte Capacity: Reservoir bottles with capacities of 100, 250, and 500 mL allow the working electrolyte volume to be matched to the test duration and circulation requirements. This provides practical flexibility for both short-term screening and longer-duration experiments.

  • Compact Laboratory Dimensions: The device is 7 cm wide and 6 cm high, occupying minimal benchtop space while retaining the essential connections required for sealed electrolyte and gas-flow testing. Its compact form supports integration into existing laboratory test setups.

Application Description Key Advantages
Zinc-Air Battery Testing Evaluates zinc-air battery performance using a transparent, sealed test mold with controlled electrolyte circulation and a defined cathode reaction area. Supports repeatable performance comparisons while helping reduce ion depletion and electrode passivation effects.
Metal Fuel Cell Reactor Research Uses the device as a compact reactor for studying electrochemical reactions involving metal fuel electrodes and circulating electrolytes. Provides a practical laboratory platform with selectable active areas and external fluid management.
High-Current Charge and Discharge Studies Circulates electrolyte during demanding charge and discharge experiments where concentration gradients may affect cell behavior. Helps reduce concentration polarization and improve mass transfer control during high-current operation.
Pure Oxygen Electrochemical Experiments Connects to a laboratory gas supply through the available 6, 8, or 10 mm tubing connectors for oxygen-fed testing protocols. Provides a controlled gas supply configuration for oxygen-related zinc-air battery and fuel cell research.
Electrolyte Circulation and Passivation Studies Investigates how continuous electrolyte replacement affects ion depletion, anode passivation, and reaction stability. Allows researchers to vary pump flow rates and reservoir capacities while monitoring electrochemical responses.
Battery and Advanced Materials Laboratories Integrates the device into academic, industrial, and materials research projects focused on electrochemical conversion and metal electrodes. Combines a compact footprint, reusable structure, and multiple reaction area options in one laboratory testing format.
Parameter Specification Remarks
Product Identifier BE06 Product identification code
Product Type Reusable Gasket-Sealed Electrolyte Cell and Transparent Zinc-Air Battery Test Mold Suitable for metal fuel cell reactor research
Mold Material Acrylic (PMMA) Transparent cell body
Width × Height 7 × 6 cm Compact laboratory dimensions
Distance Between Positive and Negative Electrodes 1.4 cm Defined electrode spacing
Tubing Connector Sizes 6 / 8 / 10 mm Supports pure oxygen testing
External Circulation Pump Flow Rate – Option 1 3–10 mL/min External pump configuration
External Circulation Pump Flow Rate – Option 2 20–65 mL/min External pump configuration
Available Reaction Areas 1 / 2 / 3 / 4 / 4.5 cm² Optional configurations
Electrolyte Reservoir Bottle Capacity 100 / 250 / 500 mL Maximum liquid capacity depends on the selected bottle
Fastener Material 304 Stainless Steel Screws and nuts


Model Variant Reaction Area Configuration Description
BE06 TR1 1 cm² Cathode reaction area: 1 cm²; anode or zinc electrode side has a reaction area of 4.5 cm².
BE06 TR2 2 cm² Standard reaction area option for the test mold.
BE06 TR3 3 cm² Standard reaction area option for the test mold.
BE06 TR4 4 cm² Standard reaction area option for the test mold.
BE06 TR4.5 4.5 cm² Standard reaction area option for the test mold.

Operating and Maintenance Precautions

The acrylic plates must not be immersed directly in ethanol or alcohol solutions. Alcohol should also not be poured directly onto the surface, as this may cause cracking or damage. If oil stains or other contaminants are present, apply a small amount of alcohol to a tissue and gently wipe the surface rather than immersing or rinsing the plate.

Ultrasonic cleaning of the acrylic plates is strictly prohibited. Following these handling requirements helps protect the transparent body and supports the long-term reuse of the device. Laboratory personnel should also select the tubing, pump flow rate, electrolyte capacity, and gas supply conditions according to the intended testing protocol and the compatibility requirements of the experimental materials.

The circulation function is designed to continuously replenish ions consumed during reactions and improve electrolyte flow throughout the test system. It also helps reduce anode passivation and concentration polarization during high-current charge and discharge processes. Actual electrochemical results depend on the electrolyte, electrode materials, gas conditions, current, and other experimental variables selected by the researcher.

Why Choose This Product

  • Controlled Experimental Architecture: The sealed cell body, defined electrode spacing, selectable reaction areas, and external circulation pathway provide researchers with practical control over key testing variables.

  • Designed for Repeated Laboratory Use: The reusable structure and 304 stainless steel fastening hardware provide a durable foundation for repeated assembly and electrochemical testing.

  • Adaptable Research Configurations: Multiple reaction areas, tubing connector sizes, pump flow rate ranges, and electrolyte reservoir capacities allow the system to accommodate different zinc-air and metal fuel cell research projects.

  • Suitable for Demanding Testing Conditions: Continuous electrolyte circulation addresses ion depletion, anode passivation, and concentration polarization, which may affect high-current experiments.

  • Convenient Integration and Support: Compact dimensions and convenient tubing connections allow the device to be incorporated into existing laboratory workflows. Application-specific configuration guidance can also help align the setup with the intended experimental requirements.



Guangdong Wevio New Energy Co., Ltd-Lithium Battery-Sodium Ion Battery -Solid State Battery - Zinc Air Battery-Material Cell Equipment Manufacturer Supplier Factory
All
  • All
  • Products
  • News
  • Presentation