Solid-State Zinc-Air Battery Test Fixture Flexible Zinc-Air Cell Mold

Solid-State Zinc-Air Battery Test Fixture Flexible Zinc-Air Cell Mold

WV-BE07 Solid-State Zinc-Air Battery Test Fixture Flexible Zinc-Air Cell Mold

Send Email:

Products DETAILS

Solid-State Zinc-Air Battery Test Fixture Flexible Zinc-Air Cell Mold

Product Overview

This solid-state zinc-air battery test fixture is a compact laboratory mold designed for assembling and observing the reaction structure of zinc-air batteries. Made of transparent acrylic (PMMA), the fixture features a smooth, clear surface that allows easier inspection of the internal arrangement during preparation and testing. Its design supports the direct stacking of the positive electrode, negative electrode, and solid electrolyte on the base plate, simplifying the assembly process and facilitating repeatable laboratory experiments.
The fixture is suitable for solid-state zinc-air battery research, flexible zinc-air cell mold applications, battery material evaluation, and advanced laboratory studies involving electrochemical cell configurations. Three reaction area options are available: 1 cm², 2 cm², and 4 cm². Customization is also available for fixtures requiring specific configurations to meet particular experimental designs.

Its compact design makes it ideal for controlled laboratory workflows where clear observation, simple assembly, and consistent component positioning are essential. The transparent acrylic construction allows visual inspection, while the defined electrode spacing and selectable reaction areas provide a structured platform for comparative testing.


Key Features

*Transparent Acrylic Construction: The fixture is made of smooth, transparent acrylic (PMMA), allowing researchers to directly observe the assembled structure and inspect the positioning of the electrodes and solid electrolyte.
*Compact Assembly Dimensions: The compact 6 × 6 cm footprint is designed for efficient laboratory operation. The positive electrode, negative electrode, and solid electrolyte can be stacked directly on top of the base plate for convenient assembly.
*Defined Electrode Spacing:** The standard distance between the positive and negative electrodes is 0.2 cm. The actual spacing is determined by the thickness of the electrolyte membrane, linking the assembly geometry to the selected solid electrolyte design.
*Multiple Reaction Area Options: The fixture is available with reaction areas of 1 cm², 2 cm², or 4 cm². These options allow laboratories to select a suitable configuration based on sample dimensions, testing objectives, and the stage of battery development.
*Clear Visual Inspection:** The transparent surface makes it easier to monitor component placement and condition during assembly. Improved visibility facilitates setup inspection and reduces uncertainty when positioning the stacked materials.
*Direct Stacking Configuration: The design supports the direct stacking of the positive electrode, negative electrode, and solid electrolyte on the upper surface of the base plate, providing a straightforward arrangement for solid-state zinc-air battery experiments.
*Customization Available: The fixture can be customized for research projects with specific dimensional or structural requirements. This is particularly useful when the standard reaction areas or assembly configurations do not meet the requirements of the planned experiments.
*Designed for Research Applications:** This fixture is specifically configured for laboratory battery development rather than general-purpose operation. Its compact dimensions, clearly defined reaction area options, and transparent construction support organized and consistent experimental workflows.


Applications
Application Description Key Advantages
Solid-State Zinc-Air Battery Research Assemble the positive electrode, negative electrode, and solid electrolyte in a controlled stacked configuration for laboratory battery research. Provides a compact and easily observable experimental assembly platform.
Zinc-Air Electrode Evaluation Compare electrode structures or material combinations using reaction area configurations of 1 cm², 2 cm², and 4 cm². Supports testing across different active area scales without changing the basic fixture design.
Solid Electrolyte Membrane Research Use the electrolyte membrane as the spacing-defining component between the positive and negative electrodes. Directly links the assembly gap to the thickness of the electrolyte membrane.
Flexible Zinc-Air Mold Development Apply the mold format in research workflows for developing flexible or customized zinc-air battery structures. Provides a simple baseline configuration with customization options to meet project-specific requirements.
Battery Material Screening Prepare small-area battery assemblies for preliminary studies of materials and cell configurations. The compact design facilitates organized small-scale laboratory experiments.
Academic and Advanced Materials Research Support teaching, laboratory demonstrations, and exploratory research involving solid-state electrochemical cells. The transparent construction improves visibility during setup and inspection.

Technical Specifications
Parameter Specification Remarks
Product Model BE07 Internal identification code for this product.
Product Type Solid-State Zinc-Air Battery Test Fixture and Flexible Zinc-Air Cell Mold Designed specifically for laboratory assembly and observation of solid-state zinc-air battery structures.
Mold Material Acrylic (PMMA) Features a smooth and transparent surface.
Overall Dimensions (W × H) 6 × 6 cm Compact fixture dimensions as specified in the product reference.
Distance Between Positive and Negative Electrodes 0.2 cm The actual distance is determined by the thickness of the electrolyte membrane.
Available Configuration BE07-1 cm² Reaction area: 1 cm².
Available Configuration BE07-2 cm² Reaction area: 2 cm².
Available Configuration BE07-4 cm² Reaction area: 4 cm².
Reaction Area Options 1 cm², 2 cm², and 4 cm² Select the configuration according to the required reaction area.
Assembly Configuration The positive electrode, negative electrode, and solid electrolyte are stacked directly on top of Plate No. 1. Facilitates convenient assembly of the stacked-cell structure.
Customization Available Please contact the supplier to discuss project-specific requirements.
Surface Characteristics Smooth and transparent Facilitates visual inspection of the assembled components.
Alcohol Cleaning Precautions Do not immerse the acrylic plate directly in ethanol or alcohol solutions. Do not pour alcohol directly onto the plate surface. These practices may cause surface cracking or damage. To remove oil stains, apply a small amount of alcohol to a tissue and gently wipe the surface.
Ultrasonic Cleaning Prohibited Do not use ultrasonic cleaning equipment to clean the acrylic plate.

The optional reaction area is the primary configuration difference among the available models. The 1 cm² version is suitable for smaller test configurations and material screening, while the 2 cm² and 4 cm² versions provide clearly defined reaction areas for experiments requiring larger active surfaces. These model identifiers distinguish each configuration by its specified reaction area while retaining the product series reference.
The 0.2 cm electrode spacing should be understood in conjunction with the specifications of the electrolyte membrane used in the experiment. Since the actual spacing is determined by the membrane thickness, researchers should confirm the intended membrane dimensions before finalizing the assembly procedure. This relationship is particularly important when comparing different solid electrolyte formulations or adapting the fixture to customized research designs.
The acrylic plates require controlled handling during cleaning and preparation. Direct immersion in ethanol or other alcohol solutions is prohibited, and alcohol should not be poured directly onto the surface. Either practice may cause cracking or more serious damage. If oil contamination occurs, the recommended cleaning method is to apply a small amount of alcohol to a tissue and carefully wipe the surface. Ultrasonic cleaning is also prohibited, as the acrylic plate must not be subjected to an ultrasonic cleaning process.
These care requirements should be incorporated into standard laboratory operating procedures. Proper handling helps preserve the smooth, transparent surface required for visual inspection. It also reduces the risk of avoidable damage during routine preparation, particularly in laboratories conducting continuous evaluations of different battery materials or electrolyte formulations.
For procurement teams, the key selection criteria are material, reaction area, overall dimensions, and electrode spacing. The transparent acrylic construction provides the required visibility, the 6 × 6 cm dimensions maintain a compact footprint, and the three available reaction area options allow the fixture to match the intended cell configuration. If the standard formats do not meet project requirements, customized solutions can be discussed before purchase.

Why Choose This Product

*Laboratory-Oriented Geometry: The clearly defined 6 × 6 cm format, 0.2 cm electrode spacing, and selectable reaction areas provide a well-defined foundation for the organized assembly of solid-state zinc-air batteries.
*High Visibility During Setup: The smooth, transparent acrylic construction allows direct observation of the stacked structure, helping researchers verify component positioning before testing.
*Configuration Flexibility: Three specified reaction area options support different experimental scales, with customization available for specialized research requirements.
*Practical Operation for Battery R&D: The compact design and direct-stacking configuration simplify preparation for repeated laboratory investigations and comparative material studies.

Select the reaction area and assembly configuration that best match your research requirements, then contact us for a quotation or a customized solid-state zinc-air battery mold solution.

Guangdong Wevio New Energy Co., Ltd-Lithium Battery-Sodium Ion Battery -Solid State Battery - Zinc Air Battery-Material Cell Equipment Manufacturer Supplier Factory
All
  • All
  • Products
  • News
  • Presentation